Leaking Santa Barbara Water Heater Pressure Relief Valve

Posted by on Dec 9, 2014 in Gas Water Heater Repair Santa Barbara, Water Heater Repair Santa Barbara

The pressure relief valve of a water heater has an essential job – making sure the water heater tank does not blow up. So with that in mind, Water Heater Repair Santa Barbara wishes to see to it house owners are aware of ways to best take care of it. They will certainly leak when the valve wears out or when the water storage tank pressure gets greater then the relief point.Hot Water Heater Repair Santa Barbara

We advise that a minimum of two times a year, homeowners test to ensure the pressure relief valve, or T&P valve as we will call it, is working correctly. All one has to do is raise the manage for a few seconds and let go of it. It must snap back to its initial position. When it is raised, one may hear the noise of pressure being released from it, similar to the sound of air coming out of a tire pump when being detached. Also, a little water might come out as well. Both are normal. If the valve has not been tested for a number of years, it may stick at first too.

However, if the handle does not snap back, or if it continues to leak some water, that is not regular. If it still leakages some, raise the handle a couple of more times to see if it does re-seat itself. You could wish to wait a day or so it see if it re-seats itself prior to assuming it has to be changed.

Hot Water Heater Repair Santa Barbara would prefer to deal with any T&P valve replacements for you, so though water heaters are typically relatively maintenance free, there are some safety precautions one need to bear in mind. With that in mind here is an overview of a pressure relief valve replacement.

1. The gas to the water heater needs to be switched off, or the breaker for an electric water heater.
2. The cold water cut-off valve needs to be closed .
3. The valve below the T&P valve has to be opened to drain some water in order to relieve some of the pressure in the storage tank.
4. The overflow pipe of the T&P valve has to be taken off. It might need to be cut off if it is soldered or firmly glued.
5. The pressure relief valve has to be unscrewed with a pipe wrench.
6. Wrap the new T&P valve with Teflon tape and screw it back in place. See to it the overflow pipe opening is placed away from the storage tank.
7. Reattach the drain pipe, also utilizing brand-new Teflon tape.
8. Turn the water back on, and examine your work for any leakages.